12 research outputs found

    Prognostic implications of left ventricular hypertrophy

    Get PDF
    Left ventricular hypertrophy (LVH) was one of the earliest studied echocardiographic characteristics of the left ventricle. As the myriad of measurable metrics has multiplied over recent years, this reliable and relevant variable can often be overlooked. In this paper, we discuss appropriate techniques for accurate analysis, underlying pathophysiology, and the contributions from various risk factors. The prognostic implications of LVH on stroke, serious arrhythmias, and sudden cardiac death are reviewed. Finally, we examine the effect of therapy to reduce LVH and the resultant clinical outcomes. (C) 2018 Elsevier Inc. All rights reserved

    Atrial Fibrillation, Heart Failure and Left Atrial Function

    Get PDF
    Background Our aim was to assess how atrial fibrillation (AF) induction, chronicity, and RR interval irregularity affect left atrial (LA) function and size in the setting of underlying heart failure (HF), and to determine whether AF effects can be mitigated by vagal nerve stimulation (VNS). Methods HF was induced by 4-weeks of rapid ventricular pacing in 24 dogs. Subsequently, AF was induced and maintained by atrial pacing at 600 bpm. Dogs were randomized into control (n = 9) and VNS (n = 15) groups. In the VNS group, atrioventricular node fat pad stimulation (310 μs, 20 Hz, 3–7 mA) was delivered continuously for 6 months. LA volume and LA strain data were calculated from bi-weekly echocardiograms. Results RR intervals decreased with HF in both groups (p = 0.001), and decreased further during AF in control group (p = 0.014), with a non-significant increase in the VNS group during AF. LA size increased with HF (p<0.0001), with no additional increase during AF. LA strain decreased with HF (p = 0.025) and further decreased after induction of AF (p = 0.0001). LA strain decreased less (p = 0.001) in the VNS than in the control group. Beat-by-beat analysis showed a curvilinear increase of LA strain with longer preceding RR interval, (r = 0.45, p <0.0001) with LA strain 1.1% higher (p = 0.02) in the VNS-treated animals, independent of preceding RR interval duration. The curvilinear relationship between ratio of preceding and pre-preceding RR intervals, and subsequent LA strain was weaker, (r = 0.28, p = 0.001). However, VNS-treated animals again had higher LA strain (by 2.2%, p = 0.002) independently of the ratio of preceding and pre-preceding RR intervals. Conclusions In the underlying presence of pacing-induced HF, AF decreased LA strain, with little impact on LA size. LA strain depends on the preceding RR interval duration

    Echocardiographic assessment of degenerative mitral stenosis: a diagnostic challenge of an Eemerging cardiac disease

    Get PDF
    Degenerative mitral stenosis (DMS) is characterized by decreased mitral valve (MV) orifice area and increased transmitral pressure gradient due to chronic noninflammatory degeneration and subsequent calcification of the fibrous mitral annulus and the MV leaflets. The “true” prevalence of DMS in the general population is unknown. DMS predominantly affects elderly individuals, many of whom have multiple other comorbidities. Transcatheter MV replacement techniques, although their long-term outcomes are yet to be tested, have been gaining popularity and may emerge as more effective and relatively safer treatment option for patients with DMS. Echocardiography is the primary imaging modality for evaluation of DMS and related hemodynamic abnormalities such as increased transmitral pressure gradient and pulmonary arterial pressure. Classic echocardiographic techniques used for evaluation of mitral stenosis (pressure half time, proximal isovelocity surface area, continuity equation, and MV area planimetry) lack validation for DMS. Direct planimetry with 3-dimensional echocardiography and color flow Doppler is a reasonable technique for determining MV area in DMS. Cardiac computed tomography is an essential tool for planning potential interventions or surgeries for DMS. This article reviews the current concepts on mitral annular calcification and its role in DMS. We then discuss the epidemiology, natural history, differential diagnosis, mechanisms, and echocardiographic assessment of DMS

    Shortening of atrioventricular delay at increased atrial paced heart rates improves diastolic filling and functional class in patients with biventricular pacing

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Use of rate adaptive atrioventricular (AV) delay remains controversial in patients with biventricular (Biv) pacing. We hypothesized that a shortened AV delay would provide optimal diastolic filling by allowing separation of early and late diastolic filling at increased heart rate (HR) in these patients.</p> <p>Methods</p> <p>34 patients (75 ± 11 yrs, 24 M, LVEF 34 ± 12%) with Biv and atrial pacing had optimal AV delay determined at baseline HR by Doppler echocardiography. Atrial pacing rate was then increased in 10 bpm increments to a maximum of 90 bpm. At each atrial pacing HR, optimal AV delay was determined by changing AV delay until best E and A wave separation was seen on mitral inflow pulsed wave (PW) Doppler (defined as increased atrial duration from baseline or prior pacemaker setting with minimal atrial truncation). Left ventricular (LV) systolic ejection time and velocity time integral (VTI) at fixed and optimal AV delay was also tested in 13 patients. Rate adaptive AV delay was then programmed according to the optimal AV delay at the highest HR tested and patients were followed for 1 month to assess change in NYHA class and Quality of Life Score as assessed by Minnesota Living with Heart Failure Questionnaire.</p> <p>Results</p> <p>81 AV delays were evaluated at different atrial pacing rates. Optimal AV delay decreased as atrial paced HR increased (201 ms at 60 bpm, 187 ms at 70 bpm, 146 ms at 80 bpm and 123 ms at 90 bpm (ANOVA F-statistic = 15, p = 0.0010). Diastolic filling time (P < 0.001 vs. fixed AV delay), mitral inflow VTI (p < 0.05 vs fixed AV delay) and systolic ejection time (p < 0.02 vs. fixed AV delay) improved by 14%, 5% and 4% respectively at optimal versus fixed AV delay at the same HR. NYHA improved from 2.6 ± 0.7 at baseline to 1.7 ± 0.8 (p < 0.01) 1 month post optimization. Physical component of Quality of Life Score improved from 32 ± 17 at baseline to 25 ± 12 (p < 0.05) at follow up.</p> <p>Conclusions</p> <p>Increased heart rate by atrial pacing in patients with Biv pacing causes compromise in diastolic filling time which can be improved by AV delay shortening. Aggressive AV delay shortening was required at heart rates in physiologic range to achieve optimal diastolic filling and was associated with an increase in LV ejection time during optimization. Functional class improved at 1 month post optimization using aggressive AV delay shortening algorithm derived from echo-guidance at the time of Biv pacemaker optimization.</p

    Pre-ejection period by radial artery tonometry supplements echo doppler findings during biventricular pacemaker optimization

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Biventricular (Biv) pacemaker echo optimization has been shown to improve cardiac output however is not routinely used due to its complexity. We investigated the role of a simple method involving computerized pre-ejection time (PEP) assessment by radial artery tonometry in guiding Biv pacemaker optimization.</p> <p>Methods</p> <p>Blinded echo and radial artery tonometry were performed simultaneously in 37 patients, age 69.1 ± 12.8 years, left ventricular (LV) ejection fraction (EF) 33 ± 10%, during Biv pacemaker optimization. Effect of optimization on echo derived velocity time integral (VTI), ejection time (ET), myocardial performance index (MPI), radial artery tonometry derived PEP and echo-radial artery tonometry derived PEP/VTI and PEP/ET indices was evaluated.</p> <p>Results</p> <p>Significant improvement post optimization was achieved in LV ET (286.9 ± 37.3 to 299 ± 34.6 ms, p < 0.001), LV VTI (15.9 ± 4.8 cm to 18.4 ± 5.1 cm, p < 0.001) and MPI (0.57 ± 0.2 to 0.45 ± 0.13, p < 0.001) and in PEP (246.7 ± 36.1 ms to 234.7 ± 35.5 ms, p = 0.003), PEP/ET (0.88 ± 0.21 to 0.79 ± 0.17, p < 0.001), and PEP/VTI (17.3 ± 7 to 13.78 ± 4.7, p < 0.001). The correlation between comprehensive echo Doppler and radial artery tonometry-PEP guided optimal atrioventricular delay (AVD) and optimal interventricular delay (VVD) was 0.75 (p < 0.001) and 0.69 (p < 0.001) respectively. In 29 patients with follow up assessment, New York Heart Association (NYHA) class reduced from 2.5 ± 0.8 to 2.0 ± 0.9 (p = 0.004) at 1.8 ± 1.4 months.</p> <p>Conclusion</p> <p>An acute shortening of PEP by radial artery tonometry occurs post Biv pacemaker optimization and correlates with improvement in hemodynamics by echo Doppler and may provide a cost-efficient approach to assist with Biv pacemaker echo optimization.</p

    An assessment of mantoux test in the diagnosis of tuberculosis in a BCG-vaccinated, tuberculosis-endemic area

    No full text
    Outpatient clinics at a tertiary care referral center where Mantoux test was done as part of pre-employment medical examination and work-up of suspected tuberculosis. Objective: To assess the utility of Mantoux test in the diagnosis of active tuberculosis, in a BCG-vaccinated, TB endemic area. Design: A prospective, case-control study, conducted over a period of two years. For statistical analysis, patients with active tuberculosis were categorized on the basis of disease site and confirmatory tests. Results: The size of induration on Mantoux test was significantly different between patients with active TB and healthy individuals (p5 mm induration; test specificity increased with increasing size of induration and was highest (86%) with induration of \u3e15 mm for both pulmonary and extrapulmonary TB. ESR was also significantly higher (p\u3c 0.05) in TB patients. Older patients without active TB were observed to have higher ESR and larger induration on MT. Conclusions: Mantoux test, with or without ESR, provides useful supportive evidence of active TB in patients with pulmonary and extrapulmonary TB in our population

    Left Atrial Size and Function in a Canine Model of Chronic Atrial Fibrillation and Heart Failure.

    No full text
    BACKGROUND:Our aim was to assess how atrial fibrillation (AF) induction, chronicity, and RR interval irregularity affect left atrial (LA) function and size in the setting of underlying heart failure (HF), and to determine whether AF effects can be mitigated by vagal nerve stimulation (VNS). METHODS:HF was induced by 4-weeks of rapid ventricular pacing in 24 dogs. Subsequently, AF was induced and maintained by atrial pacing at 600 bpm. Dogs were randomized into control (n = 9) and VNS (n = 15) groups. In the VNS group, atrioventricular node fat pad stimulation (310 μs, 20 Hz, 3-7 mA) was delivered continuously for 6 months. LA volume and LA strain data were calculated from bi-weekly echocardiograms. RESULTS:RR intervals decreased with HF in both groups (p = 0.001), and decreased further during AF in control group (p = 0.014), with a non-significant increase in the VNS group during AF. LA size increased with HF (p<0.0001), with no additional increase during AF. LA strain decreased with HF (p = 0.025) and further decreased after induction of AF (p = 0.0001). LA strain decreased less (p = 0.001) in the VNS than in the control group. Beat-by-beat analysis showed a curvilinear increase of LA strain with longer preceding RR interval, (r = 0.45, p <0.0001) with LA strain 1.1% higher (p = 0.02) in the VNS-treated animals, independent of preceding RR interval duration. The curvilinear relationship between ratio of preceding and pre-preceding RR intervals, and subsequent LA strain was weaker, (r = 0.28, p = 0.001). However, VNS-treated animals again had higher LA strain (by 2.2%, p = 0.002) independently of the ratio of preceding and pre-preceding RR intervals. CONCLUSIONS:In the underlying presence of pacing-induced HF, AF decreased LA strain, with little impact on LA size. LA strain depends on the preceding RR interval duration
    corecore